Age | Commit message (Collapse) | Author |
|
|
|
|
|
This directory isn't just about virtual memory, it's about all kinds
of memory management.
|
|
If the HPET main counter does not support full 64 bits, we should
not expect the upper 32 bit to work. This is a problem when writing
to the upper 32 bit of the comparator value, which requires the
TimerConfiguration::ValueSet bit to be set, but if it's not 64 bit
capable then the bit will not be cleared and leave it in a bad state.
Fixes #6990
|
|
SPDX License Identifiers are a more compact / standardized
way of representing file license information.
See: https://spdx.dev/resources/use/#identifiers
This was done with the `ambr` search and replace tool.
ambr --no-parent-ignore --key-from-file --rep-from-file key.txt rep.txt *
|
|
This reverts commit af2220448834fb0bff5132bf68104719819862ce.
According to the HPET specification, each theoretical comparator takes
32 bytes in the MMIO space.
Although I hardly believe that any system will implement all 32
comparators, in practice if a machine happens to have more than 3
comparators, we need to address the comparators correctly if we want to
use them.
|
|
We were calibrating it to 260 instead of 250 ticks per second (being
off by one for the 1/10th second calibration time), resulting in
ticks of only ~3.6 ms instead of ~4ms. This gets us closer to ~4ms,
but because the APIC isn't nearly as precise as e.g. HPET, it will
only be a best effort. Then, use the higher precision reference
timer to more accurately calculate how many ticks we actually get
each second.
Also the frequency calculation was off, causing a "Frequency too slow"
error with VMware.
Fixes some problems observed in #5539
|
|
Only the first 3 timers have a reserved field, the 29 other timers
do not have a reserved field.
Fixes #5530
|
|
|
|
This implements a number of changes related to time:
* If a HPET is present, it is now used only as a system timer, unless
the Local APIC timer is used (in which case the HPET timer will not
trigger any interrupts at all).
* If a HPET is present, the current time can now be as accurate as the
chip can be, independently from the system timer. We now query the
HPET main counter for the current time in CPU #0's system timer
interrupt, and use that as a base line. If a high precision time is
queried, that base line is used in combination with quering the HPET
timer directly, which should give a much more accurate time stamp at
the expense of more overhead. For faster time stamps, the more coarse
value based on the last interrupt will be returned. This also means
that any missed interrupts should not cause the time to drift.
* The default system interrupt rate is reduced to about 250 per second.
* Fix calculation of Thread CPU usage by using the amount of ticks they
used rather than the number of times a context switch happened.
* Implement CLOCK_REALTIME_COARSE and CLOCK_MONOTONIC_COARSE and use it
for most cases where precise timestamps are not needed.
|
|
* Change the register structures to use the volatile keyword explicitly
on the register values. This avoids accidentally omitting it as any
access will be guaranteed volatile.
* Don't assume we can read/write 64 bit value to the main counter and
the comparator. Not all HPET implementations may support this. So,
just use 32 bit words to access the registers. This ultimately works
around a bug in Bochs 2.6.11 that loses 32 bits of a 64 bit write to
a timer's comparator register (it internally writes one half and
clears the Tn_VAL_SET_CNF bit, and then because it's cleared it
fails to write the second half).
* Properly calculate the tick duration in calculate_ticks_in_nanoseconds
* As per specification, changing the frequency of one periodic timer
requires a restart of all periodic timers as it requires the main
counter to be reset.
|
|
|
|
|
|
This was supposed to be the foundation for some kind of pre-kernel
environment, but nobody is working on it right now, so let's move
everything back into the kernel and remove all the confusion.
|
|
|
|
This new subsystem includes better abstractions of how time will be
handled in the OS. We take advantage of the existing RTC timer to aid
in keeping time synchronized. This is standing in contrast to how we
handled time-keeping in the kernel, where the PIT was responsible for
that function in addition to update the scheduler about ticks.
With that new advantage, we can easily change the ticking dynamically
and still keep the time synchronized.
In the process context, we no longer use a fixed declaration of
TICKS_PER_SECOND, but we call the TimeManagement singleton class to
provide us the right value. This allows us to use dynamic ticking in
the future, a feature known as tickless kernel.
The scheduler no longer does by himself the calculation of real time
(Unix time), and just calls the TimeManagment singleton class to provide
the value.
Also, we can use 2 new boot arguments:
- the "time" boot argument accpets either the value "modern", or
"legacy". If "modern" is specified, the time management subsystem will
try to setup HPET. Otherwise, for "legacy" value, the time subsystem
will revert to use the PIT & RTC, leaving HPET disabled.
If this boot argument is not specified, the default pattern is to try
to setup HPET.
- the "hpet" boot argumet accepts either the value "periodic" or
"nonperiodic". If "periodic" is specified, the HPET will scan for
periodic timers, and will assert if none are found. If only one is
found, that timer will be assigned for the time-keeping task. If more
than one is found, both time-keeping task & scheduler-ticking task
will be assigned to periodic timers.
If this boot argument is not specified, the default pattern is to try
to scan for HPET periodic timers. This boot argument has no effect if
HPET is disabled.
In hardware context, PIT & RealTimeClock classes are merely inheriting
from the HardwareTimer class, and they allow to use the old i8254 (PIT)
and RTC devices, managing them via IO ports. By default, the RTC will be
programmed to a frequency of 1024Hz. The PIT will be programmed to a
frequency close to 1000Hz.
About HPET, depending if we need to scan for periodic timers or not,
we try to set a frequency close to 1000Hz for the time-keeping timer
and scheduler-ticking timer. Also, if possible, we try to enable the
Legacy replacement feature of the HPET. This feature if exists,
instructs the chipset to disconnect both i8254 (PIT) and RTC.
This behavior is observable on QEMU, and was verified against the source
code:
https://github.com/qemu/qemu/commit/ce967e2f33861b0e17753f97fa4527b5943c94b6
The HPETComparator class is inheriting from HardwareTimer class, and is
responsible for an individual HPET comparator, which is essentially a
timer. Therefore, it needs to call the singleton HPET class to perform
HPET-related operations.
The new abstraction of Hardware timers brings an opportunity of more new
features in the foreseeable future. For example, we can change the
callback function of each hardware timer, thus it makes it possible to
swap missions between hardware timers, or to allow to use a hardware
timer for other temporary missions (e.g. calibrating the LAPIC timer,
measuring the CPU frequency, etc).
|